Product characteristics
|
Number of inputs and outputs |
Number of digital outputs: 2; Number of analog outputs: 1 |
Measuring range |
-0.0124...0.25 bar |
-12.4...250 mbar |
-5...100.4 inH2O |
-1.24...25 kPa |
|
Process connection |
threaded connection G 1 external thread Aseptoflex Vario |
Application
|
System |
gold-plated contacts |
Application |
flush mountable for the food and beverage industry |
Media |
viscous media and liquids with suspended particles; liquids and gases |
Medium temperature [°C] |
-25...125; (145 max. 1h) |
Min. bursting pressure |
30000 mbar |
12044 inH2O |
3000 kPa |
|
Pressure rating |
6000 mbar |
2400 inH2O |
600 kPa |
|
Vacuum resistance [mbar] |
-1000 |
Type of pressure |
relative pressure |
No dead space |
yes |
MAWP (for applications according to CRN) [bar] |
10 |
Electrical data
|
Min. insulation resistance [MΩ] |
100; (500 V DC) |
Protection class |
III |
Reverse polarity protection |
yes |
Measuring principle |
hydrostatic |
Integrated watchdog |
yes |
2-wire
|
Operating voltage [V] |
20...32 DC |
Current consumption [mA] |
3.6...21 |
Power-on delay time [s] |
1 |
3-wire
|
Operating voltage [V] |
18...32 DC |
Current consumption [mA] |
< 45 |
Power-on delay time [s] |
0.5 |
Inputs / outputs |
Number of inputs and outputs |
Number of digital outputs: 2; Number of analog outputs: 1 |
Outputs
|
Total number of outputs |
2 |
Output signal |
switching signal; analog signal; IO-Link; (configurable) |
Electrical design |
PNP/NPN |
Number of digital outputs |
2 |
Output function |
normally open / closed; (configurable) |
Number of analog outputs |
1 |
Analog current output [mA] |
4...20, invertible; (scalable) |
Short-circuit protection |
yes |
Type of short-circuit protection |
yes (non-latching) |
Overload protection |
yes |
2-wire
|
Max. load [Ω] |
300 |
3-wire
|
Max. voltage drop switching output DC [V] |
2 |
Permanent current rating of switching output DC [mA] |
250 |
Switching frequency DC [Hz] |
125 |
Max. load [Ω] |
(Ub - 10 V) / 20 mA |
Measuring/setting range
|
Measuring range |
-0.0124...0.25 bar |
-12.4...250 mbar |
-5...100.4 inH2O |
-1.24...25 kPa |
|
Set point SP |
-12...250 mbar |
-4.8...100.4 inH2O |
-1.2...25 kPa |
|
Reset point rP |
-12.4...249.6 mbar |
-5...100.2 inH2O |
-1.24...24.96 kPa |
|
Analog start point |
-12.4...187.4 mbar |
-5...75.2 inH2O |
-1.24...18.74 kPa |
|
Analog end point |
50...250 mbar |
20.1...100.4 inH2O |
5...25 kPa |
|
In steps of |
0.2 mbar |
0.1 inH2O |
0.02 kPa |
|
Factory setting |
|
SP1 = 62.4 mbar |
rP1 = 57.4 mbar |
|
SP2 = 187.4 mbar |
rP2 = 182.4 mbar |
|
ASP = 0.0 mbar |
AEP = 250.0 mbar |
|
Accuracy / deviations
|
Switch point accuracy [% of the span] |
< ± 0,2; (Turn down 1:1) |
Repeatability [% of the span] |
< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
Characteristics deviation [% of the span] |
< ± 0,2; (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1) |
Linearity deviation [% of the span] |
< ± 0,15; (Turn down 1:1) |
Hysteresis deviation [% of the span] |
< ± 0,15; (Turn down 1:1) |
Long-term stability [% of the span] |
< ± 0,1; (Turn down 1:1; per year) |
Temperature coefficient zero point [% of the span / 10 K] |
< ± 0,05; (0...70 °C) |
Temperature coefficient span [% of the span / 10 K] |
< ± 0,15; (0...70 °C) |
Reaction times
|
Damping for the switching output dAP [s] |
0...30 |
Damping for the analog output dAA [s] |
0.01...99.99 |
2-wire |
Step response time analog output [ms] |
45 |
3-wire
|
Min. response time of switching output (dAP) [ms] |
3 |
Step response time analog output [ms] |
7 |
Interfaces
|
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.0 |
Profiles |
no profile |
SIO mode |
yes |
Required master port class |
A |
Process data analog |
1 |
Process data binary |
2 |
Min. process cycle time [ms] |
2.3 |
Supported DeviceIDs |
Type of operation |
DeviceID |
default |
257 |
|
Operating conditions
|
Ambient temperature [°C] |
-25...80 |
Storage temperature [°C] |
-40...100 |
Protection |
IP 67; IP 68; IP 69K |
Tests / approvals
|
EMC |
EN 61000-4-2 ESD |
4 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated |
10 V/m |
EN 61000-4-4 Burst |
2 kV |
EN 61000-4-5 Surge |
0,5/1 kV |
EN 61000-4-6 HF conducted |
10 V |
|
Shock resistance |
DIN IEC 68-2-27 |
50 g (11 ms) |
|
Vibration resistance |
DIN IEC 68-2-6 |
20 g (10...2000 Hz) |
|
MTTF [years] |
160 |
Note on approval |
Factory certificate available as download at www.factory-certificate.ifm |
|
UL approval |
UL approval number |
J018 |
File number UL |
E174189 |
|
Mechanical data
|
Weight [g] |
354 |
Material |
stainless steel (1.4404 / 316L); FKM; PTFE; PBT; PEI; PFA |
Materials (wetted parts) |
ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE |
Min. pressure cycles |
100 million |
Process connection |
threaded connection G 1 external thread Aseptoflex Vario |
Displays / operating elements
|
Display |
Display unit |
LED, green |
Switching status |
LED, yellow |
Function display |
alphanumeric display, 4-digit |
Measured values |
alphanumeric display, 4-digit |
|
Display unit |
mbar; kPa; inH2O; mmWS; % of the span |
Remarks
|
Pack quantity |
1 pcs. |
Electrical connection
|
Connection |
Connector: 1 x M12; Contacts: gold-plated |