Product characteristics
|
| Laser protection class |
2 |
| Housing |
rectangular |
Electrical data
|
| Operating voltage [V] |
18...30 DC; (operating voltage "supply class 2" according to cULus) |
| Current consumption [mA] |
< 150 |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Typ. lifetime [h] |
50000 |
Inputs / outputs
|
| Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
Outputs
|
| Total number of outputs |
2 |
| Electrical design |
PNP |
| Number of digital outputs |
2 |
| Output function |
normally open / normally closed; (parameterisable) |
| Max. current load per output [mA] |
200 |
| Number of analogue outputs |
1 |
| Analogue current output [mA] |
4...20; (IEC 61131-2) |
| Max. load [Ω] |
250 |
| Analogue voltage output [V] |
0...10; (IEC 61131-2) |
| Min. load resistance [Ω] |
5000 |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
pulsed |
| Overload protection |
yes |
Detection zone
|
| Max. light spot width [mm] |
15 |
| Max. light spot height [mm] |
15 |
| Light spot dimensions refer to |
10 m |
| Background suppression [m] |
0...19 |
Measuring/setting range
|
| Measuring range [m] |
0.2...10; (white paper 200 x 200 mm 90% remission) |
| Sampling rate [Hz] |
1...50 |
Interfaces
|
| Communication interface |
IO-Link |
| Transmission type |
COM2 (38,4 kBaud) |
| IO-Link revision |
1.1 |
| SDCI standard |
IEC 61131-9 |
| Profiles |
Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis |
| SIO mode |
yes |
| Required master port type |
A |
| Process data analogue |
2 |
| Process data binary |
3 |
| Min. process cycle time [ms] |
6 |
| Supported DeviceIDs |
| Type of operation |
DeviceID |
| Default |
806 |
|
Operating conditions
|
| Ambient temperature [°C] |
-10...60 |
| Protection |
IP 67 |
Tests / approvals
|
| EMC |
|
| Laser protection class |
2 |
| Notes on laser protection |
| Caution: |
laser light |
| Power: |
<= 4 mW |
| Wave length: |
650 nm |
| pulse: |
1,3 ns |
| Do not stare into beam. |
|
| Avoid exposure to the laser light. |
|
| laser class: |
2 |
| |
EN / IEC60825-1:2007 |
| |
EN / IEC60825-1:2014 |
| |
Complies with 21 CFR 1040 except for deviations pursuant to Laser Notice No. 50, dated June 2007. |
|
| MTTF [years] |
182 |
Mechanical data
|
| Weight [g] |
303 |
| Housing |
rectangular |
| Dimensions [mm] |
59 x 42 x 52 |
| Materials |
housing: diecast zinc; front lens: glass; LED window: PC |
| Lens alignment |
side lens
|
Displays / operating elements
|
| Display |
| switching status |
2 x LED, yellow |
| operation |
LED, green |
| distance value, programming |
alphanumeric display, 4-digit |
|
Accessories
|
| Accessories (optional) |
|
Remarks
|
| Remarks |
| For more information about the measuring range / application please refer to the operating instructions. |
|
| Pack quantity |
1 pcs. |
Electrical connection
|
| Connection |
Connector: 1 x M12 |
Other data
|
| Parameter |
Setting range |
Factory setting |
| Uni |
mm, m, inch |
mm |
| OU1 |
Hno, Hnc, Fno, Fnc |
Hno |
| SP1 [mm] |
200...9999 |
1000 |
| nSP1 [mm] |
200...9999 |
800 |
| FSP1 [mm] |
200...9999 |
1200 |
| OU2 |
Hno, Hnc, Fno, Fnc, I, U |
I |
| SP2 [mm] |
200...9999 |
2000 |
| nSP2 [mm] |
200...9999 |
1800 |
| FSP2 [mm] |
200...9999 |
2200 |
| ASP [mm] |
0...9999 |
0 |
| AEP [mm] |
0...9999 |
9999 |
| rATE [Hz] |
1...50 |
50 |
| dS1 [s] |
0...0.1...5 |
0 |
| dr1 [s] |
0...0.1...5 |
0 |
| dS2 [s] |
0...0.1...5 |
0 |
| dr2 [s] |
0...0.1...5 |
0 |
| dFo [s] |
0...0.1...5 |
0 |
| dIS |
d1...3 ; rd1...3; OFF |
d3 |
|
repeatability/accuracy
|
| read/write distance (mm) |
repeatability of the measured values |
|
Accuracy |
|
| |
white (90 % remission) |
grey (18 % remission) |
white (90 % remission) |
grey (18 % remission) |
| 200...1000 mm |
± 5.0 mm |
±7.5 mm |
± 15.0 mm |
± 18.0 mm |
| 1000...2000 mm |
± 5.5 mm |
±10.0 mm |
± 15.0 mm |
± 20.0 mm |
| 2000...4000 mm |
± 17.5 mm |
±22.5 mm |
± 25.0 mm |
± 32.0 mm |
| 4000...6000 mm |
± 27.5 mm |
±40.0 mm |
± 35.0 mm |
± 50.0 mm |
| 6000...10000 mm |
± 60.0 mm |
|
± 70.0mm |
|
|
| Sampling rate |
50 Hz |
| Extraneous light on the object |
< 40 klx |
|
repeatability/accuracy
|
| read/write distance (mm) |
repeatability of the measured values |
|
Accuracy |
|
| |
white (90 % remission) |
grey (18 % remission) |
white (90 % remission) |
grey (18 % remission) |
| 200...1000 mm |
± 16.5 mm |
±16.5 mm |
± 26.5 mm |
± 26.5 mm |
| 1000...2000 mm |
± 16.5 mm |
±16.5 mm |
± 26.5 mm |
± 26.5 mm |
| 2000...4000 mm |
± 30.0 mm |
±37.0 mm |
± 40.0 mm |
± 47.0 mm |
| 4000...6000 mm |
± 37.0 mm |
±57.0 mm |
± 47.0 mm |
± 67.0 mm |
| 6000...10000 mm |
± 75.0 mm |
— |
± 85.0mm |
— |
|
| Sampling rate |
50 Hz |
| Extraneous light on the object |
40...100 klx |
|
repeatability/accuracy
|
| read/write distance (mm) |
repeatability of the measured values |
|
Accuracy |
|
| |
white (90 % remission) |
grey (18 % remission) |
white (90 % remission) |
grey (18 % remission) |
| 200...1000 mm |
± 4.0 mm |
±4.5 mm |
± 14.0 mm |
± 15.0 mm |
| 1000...2000 mm |
± 4.5 mm |
±6.0 mm |
± 14.5 mm |
± 16.0 mm |
| 2000...4000 mm |
± 13.5 mm |
±14.5 mm |
± 23.5 mm |
± 24.0 mm |
| 4000...6000 mm |
± 19.0 mm |
±21.0 mm |
± 29.0 mm |
± 31.0 mm |
| 6000...10000 mm |
± 37.0 mm |
– |
± 47.0mm |
– |
|
| Sampling rate |
1 Hz |
| Extraneous light on the object |
< 40 klx |
|
repeatability/accuracy
|
| read/write distance (mm) |
repeatability of the measured values |
|
Accuracy |
|
| |
white (90 % remission) |
grey (18 % remission) |
white (90 % remission) |
grey (18 % remission) |
| 200...1000 mm |
± 10.0 mm |
± 10.0 mm |
± 20.0 mm |
± 20.0 mm |
| 1000...2000 mm |
± 10.0 mm |
± 10.0 mm |
± 20.0 mm |
± 20.0 mm |
| 2000...4000 mm |
± 17.0 mm |
± 18.0 mm |
± 27.0 mm |
± 28.0 mm |
| 4000...6000 mm |
± 22.0 mm |
± 25.0 mm |
± 32.0 mm |
± 35.0 mm |
| 6000...10000 mm |
± 37.0 mm |
– |
± 47.0mm |
– |
|
| Sampling rate |
1 Hz |
| Extraneous light on the object |
< 40...100 klx |
| - |
- |
| Range on black object (6 % remission) |
<= 4000 mm |
| - |
- |
| The values apply at |
|
| constant ambient conditions |
23 °C / 960 hPa |
| minimum power-on time in minutes |
10 |
|