Product characteristics
|
Number of inputs and outputs |
Number of digital outputs: 1; Number of analogue outputs: 1 |
Probe length L [mm] |
100...1600 |
Process connection |
G 3/4 external thread |
Application
|
Special feature |
Gold-plated contacts |
Media |
Liquids |
Dielectric constant of the medium |
≥ 1,8; (for media with a dielectric constant of 1.8...5 (e.g. oils), a coaxial pipe is needed for operation) |
Recommended media |
water; hydrous media; oils; oil-based media |
Cannot be used for |
See the operating instructions, chapter "Function and features". |
Medium temperature [°C] |
-25...80; (90 < 1 h) |
Tank pressure [bar] |
-1...16 |
MAWP (for applications according to CRN) [bar] |
16 |
Electrical data
|
Operating voltage [V] |
18...30 DC |
Current consumption [mA] |
< 30 |
Protection class |
III |
Reverse polarity protection |
yes |
Power-on delay time [s] |
< 3 |
Measuring principle |
guided wave radar |
Inputs / outputs
|
Number of inputs and outputs |
Number of digital outputs: 1; Number of analogue outputs: 1 |
Outputs
|
Total number of outputs |
2 |
Output signal |
switching signal; analogue signal; IO-Link |
Electrical design |
PNP |
Number of digital outputs |
1 |
Output function |
normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] |
2.5 |
Permanent current rating of switching output DC [mA] |
200 |
Number of analogue outputs |
1 |
Analogue current output [mA] |
4...20, invertible; (scalable) |
Max. load [Ω] |
500 |
Analogue voltage output [V] |
0...10, invertible; (scalable) |
Min. load resistance [Ω] |
2000 |
Short-circuit protection |
yes |
Type of short-circuit protection |
thermal, pulsed |
Overload protection |
yes |
Measuring/setting range
|
Probe length L [mm] |
100...1600 |
Active range A [mm] |
L-40; (when set to oil and oil based media: L-60) |
Inactive range I1 / I2 [mm] |
30 / 10; (when set to oil and oil based media: 30 / 30) |
Sampling rate [Hz] |
4 |
Setting range
|
Set point SP [mm] |
≥ 15...L-30 |
Note on setpoint SP |
when set to oil and oil based media: 35...L-30 |
|
Reset point rP [mm] |
≥ 10...L-35 |
Note on reset point rP |
when set to oil and oil based media: 30...L-35 |
|
In steps of [mm] |
5 |
Hysteresis [mm] |
> 5 |
Accuracy / deviations
|
Repeatability [mm] |
± 5 |
Measuring error [mm] |
± 7 |
Offset error [mm] |
5 |
Resolution [mm] |
1 |
Zero signal (voltage) [V] |
0 |
Zero signal (current) [mA] |
4.0 |
Full signal (voltage) [V] |
10 |
Full signal (current) [mA] |
20 |
Temperature drift per 10 K |
± 0.2 |
Interfaces
|
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 CDV |
Profiles |
no profile |
SIO mode |
yes |
Required master port type |
A |
Process data analogue |
1 |
Process data binary |
1 |
Min. process cycle time [ms] |
2.3 |
Supported DeviceIDs |
Type of operation |
DeviceID |
Default |
344 |
|
Operating conditions
|
Ambient temperature [°C] |
-25...60 |
Storage temperature [°C] |
-40...80 |
Protection |
IP 67 |
Tests / approvals
|
EMC |
DIN EN 61000-6-2 |
|
DIN EN 61000-6-3 |
in a closed metal tank |
DIN EN 61000-6-4 |
in plastic or open metal tanks |
|
Shock resistance |
DIN EN 60068-2-27 |
50 g (11 ms) / 25 g (6 ms) with reference rod 0.5 m |
|
Vibration resistance |
DIN EN 60068-2-6 |
5 g (10...2000 Hz) / 1 g (5...200 Hz) with reference rod 0.5 m |
|
MTTF [years] |
196 |
UL approval |
UL Approval no. |
H006 |
File number UL |
E174191 |
|
Mechanical data
|
Weight [g] |
437 |
Materials |
stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; PBT; PC; PEI; TPE-V |
Materials (wetted parts) |
stainless steel (1.4305 / 303); probe connection: stainless steel (1.4435 / 316L); PTFE; FKM; Sealing: NBR reinforced fibre |
Process connection |
G 3/4 external thread |
Displays / operating elements
|
Display |
Display unit |
3 x LED, green |
switching status |
1 x LED, yellow |
level |
alphanumeric display, 4-digit |
parameter setting |
alphanumeric display, 4-digit |
|
Remarks
|
Notes |
Please see the technical note under "Downloads" |
Pack quantity |
1 pcs. |
Electrical connection
|
Connection |
Connector: 1 x M12; Contacts: gold-plated |
Diagrams and graphs
|
|
|